MOTHERBOARD
IPLOG-G2E
 
  • BOX series for mounting on DIN 35 rail and flat surface, PLC in aluminum case
  • Power Input 10 to 60 VDC
  • 1x Ethernet 10/100BASE-T
  • 1x IO slot
  • 1x IF slot
IPLOG-G1
 
  • BOX series for mounting on DIN 35 rail and flat surface, PLC in aluminum case
  • Power Input 10 to 60 VDC
  • 2x Ethernet 10/100BASE-T
  • 1x IO slot
  • 1x IF slot
IPLOG-G3
 
  • BOX series for mounting on DIN 35 rail and flat surface, PLC in aluminum case
  • Power Input 10 to 60 VDC
  • 1x Ethernet 10/100BASE-T
  • 1x GSM/GPRS 2G/3G/4G-LTE
  • 2x SMA connector for 4G/LTE antenna
  • 1x IO slot
  • 1x IF slot
IPLOG-G4
 
Allow Connection of Standalone IO Modules
  • DIN series for mounting on DIN 35 rail, PLC in plastic housing UL94 V0
  • Power Input 10 to 60 VDC
  • 2x Ethernet 10/100BASE-T
  • 1x RS485
  • 1x IF slot
IPLOG-G5
 
Allow Connection of Standalone IO Modules
  • DIN series for mounting on DIN 35 rail, PLC in plastic housing UL94 V0
  • Power Input 10 to 60 VDC
  • 1x Ethernet 10/100BASE-T
  • 1x Digital Inputs (230V)
  • 1x Analog 10-bit U Input for Measuring Battery Voltage
  • 3x 10-bit Alarm / Digital Inputs (5V)
  • 1x Relay Output (NOC)
  • 2x RS485
Memory card
uSD, 16GB
 

microSD card for applications without logging:
The warranty does not cover damage to the SD card caused by repeated writes.

uSD, 16GB, SLC
 

microSD card for applications with logging:
- SLC cells suitable for repeated entries,
- rewritability 480TBW * ≈ 30,000 writes / cell,
- 16GB capacity, 
- working temperature range -40 ... + 85°C.
* Tera Bytes Written is the maximum amount of terabytes of data that an SD card can write during its lifetime according to JEDEC.

IF board on MOTHERBOARD
  -
 
Do Not Use

IF-01
 
Allow Connection of Standalone IO Modules
  • 2x RS485
IF-01G
 
Allow Connection of Standalone IO Modules
  • 2x RS485 with Galvanic Isolation
IF-02
 
  • 2x RS232 (Rx, Tx)
IF-02G
 
  • 2x RS232 (Rx, Tx) with Galvanic Isolation
IF-04G
 
Allow Connection of Standalone IO Modules
  • 1x RS485 with Galvanic Isolation
  • 1x DALI
IF-05
 
Allow Connection of Standalone IO Modules
  • 2x 10-bit Alarm / Digital Inputs (5V)
  • 1x RS485
IF-06
 
  • 1x AUDIO LINE-IN, LINE-OUT
IF-07G
 
Allow Connection of Standalone IO Modules
  • 1x RS485
  • 1x 1-Wire
IF-09
 
Allow Connection of Standalone IO Modules
  • 1x RS485
  • 1x M-BUS
IF-11
 
  • 2x 10-bit Alarm / Digital Inputs (5V)
  • 1x Wiegand
IF-12
 
  • 4x 10-bit Alarm / Digital Inputs (5V)
IF-13
 
  • 1x RS232 (Rx, Tx, RTS, CTS)
IF-13G
 
  • 1x RS232 (Rx, Tx, RTS, CTS) with Galvanic Isolation
IF-14G
 
  • 4x Digital Inputs (24V) with Galvanic Isolation
IF-15
 
  • 4x Open Collector (OC NPN)
IF-15G
 
  • 4x Open Collector (OC NPN) with Galvanic Isolation
IF-17G
 
Allow Connection of Standalone IO Modules
  • 1x RS485 with Galvanic Isolation
  • 1x RS232 (Rx, Tx) with Galvanic Isolation
IF-18G
 
Allow Connection of Standalone IO Modules
  • 1x LORA-EP1 interface
  • 1x RS485 with Galvanic Isolation
IF-21
 
  • 2x 10-bit Alarm / Digital Inputs (5V)
  • 1x Relay Output (NO/NC)
IF-22G
 
  • 2x Digital Inputs (24V) with Galvanic Isolation
  • 1x Relay Output (NO/NC)
IO board on MOTHERBOARD
  -
 
Do Not Use

DI8.1
 
  • 8x Digital Inputs (24V) with Galvanic Isolation
  • 4x Relay Output (NO 230V)
  • 2x Digital Output (OC Push-Pull)
  • 1x IF slot
AI8.1
 
  • 8x Analog 12-bit U/I Inputs
  • 2x Relay Output (NO 230V)
  • 2x Relay Output (NOC)
  • 1x IF slot
AI4.1
 
  • 4x Digital Inputs (24V) with Galvanic Isolation
  • 4x Analog 2-3 Wire RTD Inputs
  • 4x Digital SSR Output
  • 1x IF slot
BI8.1
 
  • 3x Digital Inputs (5V)
  • 8x 10-bit Alarm / Digital Inputs (5V)
  • 1x Relay Output (NOC)
  • 2x Open Collector (OC NPN)
  • 1x IF slot
RE8.1
 
  • 3x Digital Inputs (230V)
  • 8x Relay Output (NO 230V)
  • 2x Relay Output (NOC 230V)
  • 1x IF slot
AO8.1
 
  • 4x Digital Inputs (24V) with Galvanic Isolation
  • 4x Analog 12-bit U Inputs
  • 8x Analog Output 12-bit
  • 1x IF slot
PP8.1
 
  • 4x Digital Inputs (24V) with Galvanic Isolation
  • 3x 10-bit Alarm / Digital Inputs (5V)
  • 1x Relay Output (NOC)
  • 8x Digital Output (OC Push-Pull)
  • 1x IF slot
BO8.1
 
  • 3x 10-bit Alarm / Digital Inputs (5V)
  • 1x Relay Output (NOC)
  • 8x Analog / Alarm 8-bit Output
  • 2x Open Collector (OC NPN)
  • 1x IF slot
RE8.2E
 
  • 8x Relay Output (NOC)
RE8.2
 
  • 8x Relay Output (NOC)
  • 1x IF slot
BI8.4
 
  • 8x 10-bit Alarm / Digital Inputs (5V)
  • 4x Relay Output (NOC)
  • 1x IF slot
IF board on IO on MOTHERBOARD
  -
 
Do Not Use

IF-10G
 
  • 1x KNX
IF-12
 
  • 4x 10-bit Alarm / Digital Inputs (5V)
IF-14G
 
  • 4x Digital Inputs (24V) with Galvanic Isolation
IF-15
 
  • 4x Open Collector (OC NPN)
IF-15G
 
  • 4x Open Collector (OC NPN) with Galvanic Isolation
IF-21
 
  • 2x 10-bit Alarm / Digital Inputs (5V)
  • 1x Relay Output (NO/NC)
IF-22G
 
  • 2x Digital Inputs (24V) with Galvanic Isolation
  • 1x Relay Output (NO/NC)



GSM antenna
  -
 
Do Not Use

ANT-OH-LTE-5dB
 
  • 2x 4G/LTE antenna
KIT-2xANT-LTE-2.4dB
 
  • 2x 4G/LTE antenna
ANT-OH-2G/3G-2dB
 
  • 1x 2G/3G antenna
ANT-2G/3G-2dB
 
  • 1x 2G/3G antenna



Standalone IO Modules

Standalone IO modules Can Not be Connected - choose proper IF board